Specification | Standard | Plus | Pipe |
---|---|---|---|
Application1 | Regular Canals | Open Channels | Pipes & Culverts |
Acoustics Beams — Along-Axis (2) | 25° off vertical axis, along axis of channel | 25° off vertical axis, along axis of channel | 25° off vertical axis, along axis of channel |
Acoustics Beams — Skew (2) | 60° off vertical and 60° off center axis of channel | 60° off vertical and 60° off center axis of channel | 37° off vertical and 45° off center axis of channel |
Velocity — Sampling Range | 0.05 – 1.5 m | 0.16 - 5 ft | 0.05 – 5.0 m | 0.16 - 16 ft | 0.05 – 5.0 m | 0.16 - 16 ft |
Number of cells | 1 | Up to 100 | Up to 100 |
Cell Size | Dynamic integrated | 2 cm – 10 cm | 0.8 - 4 in | 2 cm – 10 cm | 0.8 - 4 in |
Velocity — Range | ±5 m/s | 16 ft/s | ±5 m/s | 16 ft/s | ±5 m/s | 16 ft/s |
Velocity — Resolution | 0.0001 m/s | 0.0003 ft/s | 0.0001 m/s | 0.0003 ft/s | 0.0001 m/s | 0.0003 ft/s |
Velocity — Accuracy | ±1% of measured velocity, ±0.5 cm/s | 0.2 in/s | ±1% of measured velocity, ±0.5 cm/s | 0.2 in/s | ±1% of measured velocity, ±0.5 cm/s | 0.2 in/s |
Advanced Data Reprocessing | N/A | Yes | Yes |
Increased Number of Data Fields | N/A | Yes | Yes |
Vertical Beam Range2 | 0.05 – 1.5 m | 0.2 - 5 ft | 0.05 - 5.0 m | 0.2 - 16 ft | 0.05 - 5.0 m | 0.2 - 16 ft |
Water Level Accuracy | 0.1% of measured depth or ±0.003 m (0.01 ft), whichever is greater | 0.1% of measured depth or ±0.003 m (0.01 ft), whichever is greater | 0.1% of measured depth or ±0.003 m (0.01 ft), whichever is greater |
Pressure — Range3 | 30 m | 98 ft; 42 psi | 30 m | 98 ft; 42 psi | 30 m | 98 ft; 42 psi |
Pressure — Accuracy | 0.1% of full scale | 0.1% of full scale | 0.1% of full scale |
Communications | RS232, SDI-12, Modbus, Analog (via optional Flow Display) | RS232, SDI-12, Modbus, Analog (via optional Flow Display) | RS232, SDI-12, Modbus, Analog (via optional Flow Display) |
Data Storage | 4GB (approximately 1-yr) | 4GB (approximately 1-yr) | 4GB (approximately 1-yr) |
Operating Temperature | -5 to 60°C | 23-140°F | -5 to 60°C | 23-140°F | -5 to 60°C | 23-140°F |
Temperature & Tilt Sensors | Yes | Yes | Yes |
1The SonTek-IQ Series is not IS or ATEX certified. Do not use in areas with explosion risk.
2Water level measured primarily with vertical beam, with pressure sensor for redundancy.
3For use in pressurized pipes. Housing rated to 42 psi.
Become an instant velocity-indexing pro! FlowPack allows you to generate easy to interpret Velocity-Index ratings. Promising to make your data reporting process a whole lot friendlier (and faster), FlowPack also provides a simple method to store flow, velocity, and stage measurements — all through one software program. FlowPack can produce comprehensive reports that assist you in making better, more informed decisions.